电机启动计算
-
电机
- 电机
| 电动机启动计算 | |||||||||
| 系统容量视为无穷大,变压器为630KVA油浸变压器,上级母线距车间母线采用2根185电缆连接(150米),电动机距车间母线50米。 | |||||||||
| 系统示意图1-1 | |||||||||
| 一、计算数据 | |||||||||
| 1、 电动机频繁启动 | |||||||||
| (1) 选用电机为75KW三相鼠笼异步电机 | |||||||||
| 主要电气参数 | |||||||||
| S" | SrT | xT | Skm | Qfh | Sfh | Xl | SqM | Sq | |
| ∽ | 1 | 0.055 | 18.18 | 0.480 | 0.800 | 0.034 | 0.645 | 0.561 | |
| IrM | UrM | kq | S | uqm | uqM | ||||
| 0.140 | 0.380 | 7 | 150 | 0.971 | 0.844 | ||||
| (2) 选用电机为55KW三相鼠笼异步电机 | |||||||||
| 主要电气参数 | |||||||||
| S" | SrT | xT | Skm | Qfh | Sfh | Xl | SqM | Sq | |
| ∽ | 0.63 | 0.045 | 14.00 | 0.302 | 0.504 | 0.013 | 0.470 | 0.450 | |
| IrM | UrM | kq | S | uqm | uqM | ||||
| 0.102 | 0.380 | 7 | 150 | 0.969 | 0.93 | ||||
| 2、 电动机不频繁启动 | |||||||||
| (1) 选用电机为132KW三相鼠笼异步电机 | |||||||||
| 主要电气参数 | |||||||||
| S" | SrT | xT | Skm | Qfh | Sfh | Xl | SqM | Sq | |
| ∽ | 0.63 | 0.045 | 14.00 | 0.302 | 0.504 | 0.013 | 1.129 | 1.022 | |
| IrM | UrM | kq | S | uqm | uqM | ||||
| 0.245 | 0.380 | 7 | 150 | 0.933 | 0.84 | ||||
| (2) 选用电机为110KW三相鼠笼异步电机 | |||||||||
| 主要电气参数 | |||||||||
| S" | SrT | xT | Skm | Qfh | Sfh | Xl | SqM | Sq | |
| ∽ | 0.63 | 0.045 | 14.00 | 0.302 | 0.504 | 0.014 | 0.940 | 0.862 | |
| IrM | UrM | kq | S | uqm | uqM | ||||
| 0.204 | 0.380 | 7 | 120 | 0.943 | 0.86 | ||||
| 二、计算过程 | |||||||||
| 1、 电动机不频繁启动 | |||||||||
| Skm=SrT/(xT+SrT/S")=14 (MVA) | |||||||||
| (1) 选用电机为75KW三相鼠笼异步电机(SqM=0.645 MVA)。 | |||||||||
| Xl=(0.07+6.3/185)*0.5*0.15+(0.07+6.3/70)*0.05=0.031+0.008=0.039 | |||||||||
| Sq=1/(1/SqM+Xl/U2m)=0.549 | |||||||||
| Qfh=0.302 | 0 | ||||||||
| uqm=(Skm+Qfh)/(Skm+Qfh+Sq)=14.302/14.851=0.963 | |||||||||
| uqM =0.963*Sq/SqM=0.963*0.549/0.645=0.82 | |||||||||
| (2) 选用电机为55KW三相鼠笼异步电机(SqM=0.470MVA)。 | |||||||||
| Xl=(0.07+6.3/185)*0.5*0.15+(0.07+6.3/50)*0.05=0.031+0.010=0.041 | |||||||||
| Sq=1/(1/SqM+Xl/U2m)=0.295 | |||||||||
| Qfh=0.302 | |||||||||
| uqm=(Skm+Qfh)/(Skm+Qfh+Sq)=14.302/14.718=0.972 | |||||||||
| uqM =0.972*Sq/SqM=0.972*0.416/0.472=0.86 | |||||||||
| 故电机功率为55KW三相鼠笼异步电机可直接启动。 | |||||||||
| 2、 电动机频繁启动 | |||||||||
| Skm=SrT/(xT+SrT/S")=14 (MVA) | |||||||||
| (1) 选用电机为37KW三相鼠笼异步电机(SqM=0.322 MVA)。 | |||||||||
| Xl=(0.07+6.3/185)*0.5*0.15+(0.07+6.3/25)*0.05=0.031+0.016=0.047 | |||||||||
| Sq=1/(1/SqM+Xl/U2m)=0.292 | |||||||||
| Qfh=0.302 | |||||||||
| uqm=(Skm+Qfh)/(Skm+Qfh+Sq)=14.302/14.594=0.980 | |||||||||
| uqM =0.98*Sq/SqM=0.98*0.292/0.322=0.89 | |||||||||
| (2) 选用电机为30KW三相鼠笼异步电机(SqM=0.263 MVA)。 | |||||||||
| Xl=(0.07+6.3/185)*0.5*0.15+(0.07+6.3/16)*0.05=0.031+0.023=0.054 | |||||||||
| Qfh=0.302 | |||||||||
| Sq=1/(1/SqM+Xl/U2m)=0.239 | |||||||||
| uqm=(Skm+Qfh)/(Skm+Qfh+Sq)=14.302/14.541=0.984 | |||||||||
| uqM =0.984*Sq/SqM=0.984*0.239/0.263=0.90 | |||||||||
| 故电机功率为30KW三相鼠笼异步电机可直接启动。 | |||||||||
| 工厂配电设计手册150页表6-16,钢铁手册下册193页表23-4 | |||||||||